Imo Resolution Mepc. 107 (49) Ows 15ppm Bilge Alarm Bilgmon 488

Product Details
Customization: Available
Certificate: Dnv Certification
Delivery Time: in Stock
Manufacturer/Factory, Trading Company

360° Virtual Tour

Diamond Member Since 2013

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Type of Ownership
Limited Company
Management System Certification
ISO 9000, QC 080000
  • Imo Resolution Mepc. 107 (49) Ows 15ppm Bilge Alarm Bilgmon 488
  • Imo Resolution Mepc. 107 (49) Ows 15ppm Bilge Alarm Bilgmon 488
  • Imo Resolution Mepc. 107 (49) Ows 15ppm Bilge Alarm Bilgmon 488
  • Imo Resolution Mepc. 107 (49) Ows 15ppm Bilge Alarm Bilgmon 488
  • Imo Resolution Mepc. 107 (49) Ows 15ppm Bilge Alarm Bilgmon 488
  • Imo Resolution Mepc. 107 (49) Ows 15ppm Bilge Alarm Bilgmon 488
Find Similar Products

Basic Info.

Model NO.
BILGMON 488
Pullution Sources
Water Pollution Control
Transport Package
Carton Box
Specification
CCS & CE
Trademark
Deyuan
Origin
China
Production Capacity
1000PCS/Month

Product Description

IMO Resolution MEPC.107(49) OWS 15ppm Bilge Alarm BILGMON 488
Imo Resolution Mepc. 107 (49) Ows 15ppm Bilge Alarm Bilgmon 488
15ppm Oil Content Meter Bilgmon 488 Bilge Alarm

A 15ppm Bilge Alarm is normally used in connection to a ship's oil filtering equipment (also known as "bilge water separator"), monitoring the oil content of the separated/filtered water and stopping the discharge into the sea if the oil content exceeds 15ppm (parts per million).

The 15 ppm bilge alarm type "BilgMon 488" is type approved for this purpose according to latest IMO Rules MEPC.107(49).

Furthermore the 15ppm bilge alarm can in principle be used as a simple oil content alarm for other applications where the water does not contain solids or other substances disturbing the operation.

Main performance indicators of 488 Bilge Alarm

1) Measuring range: 0-30ppm (display range 0-80ppm)
2) Measurement precision: (15ppm alarm) ± 5ppm (meet the IMO standard)
3) Display type: LED digital tube
4) indication: 4 red LED
5) 2-way alarm relay
6) Rated capacity of relay contact 250VAC 3A (non-emotional)
7) Response time ≤ 5 seconds
8) Output signal 4-20mA
9) Environment temperature 0 - 55 Celsius degree
10) Bilge water Alarm Relative humidity≤ 93%
11) Sample liquid temperature 1 - 55 Celsius degree
12) Sample liquid pressure 0.1-0.6MPa
13) Sample liquid flow of 0.1-4L / min
14) Protection class IP55
15) Main power supply 220/110VAC 50Hz/60Hz
16) Power Consumption ≤ 20VA
17) Overall dimension 400mm × 300mm × 160mm
18) Meet the standard IMO. Res. MEPC. 107 (49) resolution
More 15ppm bilge water alarm can be offered, pls contact us for more details

Cheaper to Replace than Repair the Bilge Alarm

When a complete new bilge water separator is delivered to an existing ship or to a new building, the separator already contains a 15 ppm bilge alarm. However, when the 15ppm bilge alarm on an existing ship is broken beyond repair, or repairing the bilge alarm would be almost as expensive as a new one, the best solution is to replace the old alarm with a new one.

Spare part list for the Bilgmon488

We deliver all the necesarry spares for the bilgemon488 quickly and cost effective using below product code: 

  • Sensor unit: BM201001A-1
  • Master Unit: BM201001A-2
  • Magnetic valve assembly: BM201001A-3
  • Calibration check kit: BM201001A-4

Rules and Regulations for 15 ppm Bilge Alarms

According to MARPOL Annex I, ships of 400 gross tonnage and above must be fitted with a bilge water separator, and on ships of 10000 gross tonnage and above the bilge water separator must additionally be fitted with a 15 ppm bilge alarm. However, ships between 400 and 10000 gross tonnage are also required to have the 15ppm alarm in order to be allowed to operate the bilge water separator when the ship is in one of the following "Special Areas" as defined by MARPOL.

  • The Mediterranean  Sea
  • The Black Sea
  • The Baltic Sea and the North West European waters
  • The Red Sea and the Gulf of Aden
  • The Arabian Gulf
  • The Oman area of the Arabian Sea.

For details see Reg.14 & 15 of MARPOL Annex I (Consolidated Edition 2006).

Ships built before 2005 may operate with equipment meeting the requirements of older IMO Rules, but ships built in 2005 and later must be fitted with bilge separators and 15ppm bilge alarms type approved According to MEPC.107(49).

For details see paragraph 1.3 of MEPC.107(49).


Imo Resolution Mepc. 107 (49) Ows 15ppm Bilge Alarm Bilgmon 488
Imo Resolution Mepc. 107 (49) Ows 15ppm Bilge Alarm Bilgmon 488
Imo Resolution Mepc. 107 (49) Ows 15ppm Bilge Alarm Bilgmon 488
Imo Resolution Mepc. 107 (49) Ows 15ppm Bilge Alarm Bilgmon 488

Imo Resolution Mepc. 107 (49) Ows 15ppm Bilge Alarm Bilgmon 488
Imo Resolution Mepc. 107 (49) Ows 15ppm Bilge Alarm Bilgmon 488
Imo Resolution Mepc. 107 (49) Ows 15ppm Bilge Alarm Bilgmon 488

 Imo Resolution Mepc. 107 (49) Ows 15ppm Bilge Alarm Bilgmon 488

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier
Product Groups
More